It exists in three interface formats: the HPE SSA GUI, the HPE SSA CLI, and HPE SSA Scripting. All formats provide support for configuration tasks. Some of the advanced tasks are available in only one format. The diagnostic features in HPE SSA are also available in the standalone software HPE Smart Storage Administrator Diagnostics Utility CLI.
HPE SSA replaces the existing HP Array Configuration Utility, or ACU, with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online. HPE Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of HPE SSA, with the appropriate firmware. HPE SSA will
Make sure that a Smart Array P-class Gen10 controller is installed. Make sure that you have the following items available: Storage controller backup power cable (ships with the storage controller) Energy pack option. If you are installing the HPE Smart Storage Hybrid Capacitor, verify that the system BIOS meets the minimum firmware requirements.
The capacitor pack can support up to two devices. This server supports the HPE Smart Storage Hybrid Capacitor with the 145mm cable. Before installing the HPE Smart Storage Hybrid Capacitor, verify that the system BIOS meets the minimum firmware requirements to
Hewlett Packard Enterprise offers the HPE Smart Storage Battery as a centralized backup power source options to back up write cache content on the controllers in case of an unplanned server power outage. Once installed, the status of the energy pack displays in HPE iLO iLO.
The health of the energy pack can be viewed using any of the following options: HPE iLO GUI under the Power & Thermal > Power. The controller''s GUI & CLI tools along with HPE iLO Redfish under StorageController > CacheSummary. HPE iLO Redfish Chassis resource. Upon starting, the storage controllers exchange information with HPE BIOS during POST and
Use this procedure to remove and replace either the HPE Smart Storage battery or the HPE Smart Storage Hybrid Capacitor. NOTE: System ROM and firmware messages might display "energy pack" in place of "Smart Storage Battery." Energy pack refers to both HPE Smart Storage batteries and HPE Smart Storage Hybrid capacitors.
Updating firmware or system ROM. Configuring the server. Configuring storage controllers. Managing the HPE NS204i Boot Device. Deploying an OS. This server supports the following power options—collectively known as energy pack: HPE Smart Storage Battery. HPE Smart Storage Hybrid Capacitor. One energy pack supports multiple devices.
The HPE Smart Storage Administrator (HPE SSA) is a web-based application that helps you configure, manage, diagnose, and monitor HPE ProLiant Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), HPE Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. HPE
HPE Persistent Memory module, 128 GB 844071-001 HPE Persistent Memory module, 256 GB 844072-001 HPE Persistent Memory module, 512 GB 844073-001 Processor heatsink spare parts Customer self repair: no Description Spare part number Front processor heatsink (processors 1 and 2) 873081-001 Rear processor heatsink (processors 3 and 4) 873082-001
Updating firmware or system ROM. Configuring the server. Configuring storage controllers. Managing the HPE NS204i-u Boot Device. Deploying an OS. This server supports the following power options—collectively known as energy pack: HPE Smart Storage Battery. HPE Smart Storage Hybrid Capacitor. One energy pack supports multiple devices.
HPE Smart Storage Administrator Diagnostics Utility CLI. Installing the utility. verify that the firmware for the controller and the firmware for iLO are the latest versions. To resolve the issue, follow the steps in the flowchart. Energy pack issues for HPE Smart Array controllers. Symptom. Cause. Action. Was this information helpful?
HPE SSACLI replaces the existing HP Array Configuration CLI Utility, or ACUCLI, with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online. HPE Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of HPE SSACLI, with the appropriate firmware
The exhaustive list of HPE firmware binary types is presented in a Help pop-up window of the iLO Graphical User Interface: Firmware & OS Software --> Update Firmware (right pane) --> ? --> Server firmware file type details. Smart Components. HPE and partner vendor (Intel, Mellanox, Marvell, etc.) firmware binaries are packaged in Smart Components.
· Online firmware updates for controllers, backplanes, and drives. Models. HPE MR416i-p Gen11 x16 Lanes 8GB Cache PCI SPDM Plug-in Storage Controller. P47777-B21. Notes: An HPE Smart Storage energy pack (available in both battery and hybrid capacitor options) is optional with the HPE MR416i-o Gen11 and HPE MR416i-p Gen11 storage
HPE GreenLake; HPE Complete Care Service; HPE Tech Care Service; Obtaining the iLO firmware image file. Obtaining supported server firmware image files. Smart Storage Energy Pack list. Power monitoring. High Efficiency Mode. Viewing fan information. Fan details. Fans. Temperature information .
Under the Power tab, it says that the Smart Storage Battery has failed still - despite the new ones being installed this morning. I''m going to try and install the latest HPE Service Pack for the Gen9. I''ll post the outcome here. edit - installed the latest service pack and ilo update, problem still persists though.
The HPE Smart Storage Hybrid Capacitor supports both HPE SR and MR storage controllers.. The capacitor pack can support up to three devices. This server supports the HPE Smart Storage Hybrid Capacitor with the 260 mm cable.. Before installing the HPE Smart Storage Hybrid Capacitor, verify that the system BIOS meets the minimum firmware requirements to support
Updating firmware or system ROM. Configuring the server. Configuring storage controllers. Energy pack spare parts. Subtopics. HPE Smart Storage Hybrid Capacitor spare part; HPE Smart Storage Battery spare part; Related Products. HPE ProLiant DL380 Gen11. On This Page.
Based on the document this issue only observed on the Gen9 servers which uses iLO firmware of 2.40 or 2.42 and running on System ROM 2.20 (or earlier). As resolution the HPE iLO should be updated to the Firmware version of 2.44 or earlier. Link to HPE iLO 4 page for downloading firmware and tools.
The HP Smart Storage Administrator (HP SSA) is a web-based application that helps you configure, manage, diagnose, and monitor HP ProLiant Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), HP Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. HP SSA replaces
Connect the energy pack cable to the system board and secure it in the cable clamp.; If removed, install the HPE NS204i-u Boot Device. Make sure that all the system cables that are routed through the front cable channel are properly secured in the metal cable tabs and cable clamps.
Updating firmware or system ROM. Configuring the server. Configuring storage controllers. Deploying an OS. Configuring security. Optimizing the server. This server supports the following power options—collectively known as energy pack: HPE Smart Storage Battery. HPE Smart Storage Hybrid Capacitor. One energy pack supports multiple devices.
The HPE Smart Storage Hybrid Capacitor is only supported on Gen10 and later servers. One energy pack option can support multiple devices. An energy pack option is required for 900 series controllers. Once installed, the status of the energy pack displays in HPE iLO.
One energy pack option can support multiple devices. An energy pack option is required for 900 series controllers. Once installed, the status of the energy pack displays in HPE iLO. For more information, see the HPE iLO user guide on the Hewlett Packard Enterprise website.
NOTE: System ROM and firmware messages might display "energy pack" in place of "Smart Storage Battery." Energy pack refers to both HPE Smart Storage batteries and HPE Smart Storage Hybrid capacitors. Make sure that a supported Smart Array P-class Gen10 controller is installed. The installation is complete.
Install the energy pack option. Route and connect the cable. Do not connect the energy pack while the server is operating. Verify that all power to the server has been removed. Install the fan cage. Install the access panel. Install the server into the rack. Connect each power cord to the server. Connect each power cord to the power source.